- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0001000000000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Chatterjee, Baibhab (1)
-
Das, Debayan (1)
-
K, Gaurav Kumar (1)
-
Krishna, Jayant (1)
-
Modak, Nirmoy (1)
-
Nath, Mayukh (1)
-
Sen, Shreyas (1)
-
Xiao, Shulan (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
To solve the challenge of powering and communication in a brain implant with low end-end energy loss, we present Bi-Phasic Quasi-static Brain Communication (BP-QBC), achieving < 60dB worst-case channel loss, and ~41X lower power w.r.t. traditional Galvanic body channel communication (G-BCC) at a carrier frequency of 1MHz (~6X lower power than G-BCC at 10MHz) by blocking DC current paths through the brain tissue. An additional 16X improvement in net energy-efficiency (pJ/b) is achieved through compressive sensing (CS), allowing a scalable (6kbps-10Mbps) duty-cycled uplink (UL) from the implant to an external wearable, while reducing the active power consumption to 0.52μW at 10Mbps, i.e. within the range of harvested body-coupled power in the downlink (DL), with externally applied electric currents < 1/5th of ICNIRP safety limits. BP-QBC eliminates the need for sub-cranial interrogators, utilizing quasi-static electrical signals for end-to-end BCC, avoiding transduction losses.more » « less
An official website of the United States government
